Small size LGA8 package and with I2C digital interface barometer and altimeter
| Parameter | Symbol | Condition | Min | Typ | Max | Units | ||||||||||||||||||
| Operating temperature range | TA | operational | -40 | 25 | +85 | °C | ||||||||||||||||||
| full accuracy | 0 | 65 | ||||||||||||||||||||||
|
Operating pressure range |
P | full accuracy | 300 | 1100 | hPa | |||||||||||||||||||
| Sensor supply voltage | VDD | 1.8 | 3.6 | V | ||||||||||||||||||||
| Supply current | IDD,LP | 1Hz, lowest osr_p and osr_t | 5.4 | pA | ||||||||||||||||||||
| Peak current | Ipeak |
during pressure measurement |
760 | pA | ||||||||||||||||||||
| Current at temperature measurement | IDDT | 541 | pA | |||||||||||||||||||||
| Sleep current | IDDSL | 25°C | 0.1 | 0.3 | pA | |||||||||||||||||||
| Relative accuracy | Arel |
700 …900hPa 25 …40°C |
±0.03 | hPa | ||||||||||||||||||||
| ± 0.25 | m | |||||||||||||||||||||||
| Offset temperature coefficient | TCO | 900hPa 25 …40°C | ± 0.3 | Pa/K | ||||||||||||||||||||
| ± 2.5 | cm/K | |||||||||||||||||||||||
| Absolute accuracy pressure |
300 … 1100hPa 0 …60°C |
± 1.0 | hPa | |||||||||||||||||||||
| Resolution of output data in O4 ultra high resolution mode | RP | Pressure | 0.095 | Pa | ||||||||||||||||||||
| RT | Temperature | 0.01 | °C | |||||||||||||||||||||
| Noise in pressure | VP,full | Full bandwidth, O4 ultra high resolution | 1.0 | Pa | ||||||||||||||||||||
| 8.3 | cm | |||||||||||||||||||||||
| VP, filtered | Lowest bandwidth, O4 ultra high resolution | 0.2 | Pa | |||||||||||||||||||||
| 1.7 | cm | |||||||||||||||||||||||
|
Absolute
accuracy temperature |
AT | @25℃ | ±0.5 | °C | ||||||||||||||||||||
| 0 …+65℃ | ± 1.0 | °C | ||||||||||||||||||||||
| PSRR (DC) | PSSR | Full VDD range | ±0.005 | Pa/mV | ||||||||||||||||||||
| Long term stability | ΔPstab | 12 months | ±TBD | hPa | ||||||||||||||||||||
| Solder drifts | -0.5 | +2 | hPa | |||||||||||||||||||||
|
Possible rate |
sampling | fsample | 157 | 182 | TBD | Hz | ||||||||||||||||||
| File Name | Online reading | File download |
| Digital Pressure Sensor XY100A |
Jul 12,2024
Two-Wire Hall Switch1. Long terms work life2. Stability and high sensitivity3. Connect with MCU I/O ADC4. High work voltage from 3.0~30V
Mar 19,2019
Measuring principle of corrosive liquid level sensor: extreme short microwave pulse withvery low energy is transmitted and received through antenna system. Radar wavestravel at the speed of light. Run...
Apr 02,2019
The pressure transmitter is a kind of on-site instrument which directly contacts the measured medium. It is often used in high temperature, low temperature, corrosion, vibration, impact, and other env...
Jul 07,2019
Withthe development of industrial automation, various industries are graduallymoving towards informationization and intellectualization. Driven by the market, pressure transmitters are constantly deve...